Where to Buy an MRI Machine in India
Buying an MRI machine is a high-value, long-term infrastructure decision for hospitals and diagnostic centers. The right source affects image quality, patient safety, regulatory compliance, uptime, and total cost of ownership—not just the purchase price. This guide explains where to buy an MRI machine in India, what types of sellers exist, how pricing works, and what technical and regulatory factors decision-makers must verify before purchase.
Where to Buy an MRI Machine in India
Certified suppliers act as intermediaries between OEMs and buyers, especially in regional markets.
Role of suppliers
- Equipment sourcing (new or refurbished)
- Import coordination
- Installation supervision
- AMC and parts support
Industry example
- Sasha Health Care, India-based medical equipment supplier with experience in MRI, CT, and advanced imaging systems.
Authorized medical equipment suppliers bridge OEM technology with local installation, regulatory approvals, and service execution.
Understanding the MRI Machine Buying Landscape
An MRI (Magnetic Resonance Imaging) system is a complex medical imaging device governed by international safety standards, local radiation regulations, and OEM-specific service protocols.
In India, MRI machines are typically purchased through three primary channels:
- OEM-authorized suppliers
- Certified refurbished equipment providers
- Government or institutional procurement frameworks
MRI machines in India are sold primarily through OEM-authorized distributors or certified refurbished equipment suppliers, not through open retail channels.
Option 1: OEM-Authorized MRI Machine Suppliers
OEM-authorized suppliers sell new MRI systems directly from manufacturers or through their certified partners.
Major MRI OEMs Active in India
- Siemens Healthineers (MAGNETOM series)
- GE HealthCare (SIGNA series)
- Philips Healthcare (Ingenia series)
- Canon Medical Systems (Vantage series)
These suppliers operate through Indian subsidiaries or licensed distributors located in major medical hubs such as Delhi NCR, Mumbai, Bengaluru, Chennai, and Hyderabad.
What You Get
- Factory-new system
- Manufacturer warranty
- OEM-certified installation
- Long-term service contracts (AMC/CMC)
- Software upgrades and safety updates
Typical Pricing (India)
- 1.5 Tesla MRI: ₹3.5 crore – ₹5.5 crore
- 3 Tesla MRI: ₹5 crore – ₹ 8 crore
(Prices vary based on gradients, coils, software packages, and site readiness.)
A new 1.5 Tesla MRI machine in India typically costs between ₹6.5 crore and ₹9.5 crore, excluding civil and shielding work.
Option 2: Certified Refurbished MRI Machine Suppliers
Refurbished MRI systems are widely used by diagnostic centers and tier-2 or tier-3 hospitals due to lower capital expenditure.
A certified refurbished MRI machine is de-installed, reconditioned, tested, and reinstalled under controlled engineering standards.
Common Refurbished Models in India
- Siemens MAGNETOM Avanto 1.5T
- Siemens MAGNETOM Essenza 1.5T
- GE SIGNA HDxt 1.5T
- Philips Achieva 1.5T
Typical Pricing (India)
- 1.5 Tesla refurbished MRI: ₹2.2 crore – ₹4.5 crore
- 3 Tesla refurbished MRI: ₹5.5 crore – ₹8 crore
What to Verify
- Magnet ramp-down and ramp-up history
- Gradient coil integrity reports
- RF coil inventory and condition
- OEM-trained service engineers
- Availability of helium refill support
Certified refurbished MRI machines in India cost 40–60% less than new systems but require strict verification of magnet, gradient, and service support.
Option 3: Government and Institutional Procurement
Large public hospitals and medical colleges usually acquire MRI machines through:
- Government tenders (GEM, state health departments)
- PSU procurement programs
- PPP (Public–Private Partnership) models
This route prioritizes compliance, lowest bid, and long-term service guarantees, but involves longer procurement cycles.
Installation and Site Readiness Requirements
MRI machines require specialized infrastructure before delivery.
Core Requirements
- RF-shielded MRI room (copper shielding)
- Quench pipe and venting system
- Chiller and HVAC with temperature control
- Power supply with isolation transformer
- Magnetic safety zoning (Zone I–IV)
Space Requirements
- 1.5T MRI: ~1,200–1,500 sq. ft.
- 3T MRI: ~1,500–2,000 sq. ft.
MRI installation requires RF shielding, controlled HVAC, and magnetic safety zoning, making site readiness as critical as machine selection.
Regulatory and Safety Compliance in India
MRI systems are non-ionizing but still regulated.
Mandatory Compliance
- AERB safety guidelines (India)
- IEC 60601-2-33 standard
- OEM safety documentation
- Trained MRI safety officer on-site
Hospitals must maintain MRI safety protocols, ferromagnetic screening, and emergency quench procedures.
Choosing Between 1.5 Tesla and 3 Tesla MRI
| Parameter | 1.5 Tesla | 3 Tesla |
|---|---|---|
| Clinical Use | Routine neuro, MSK, body imaging | Advanced neuro, cardiac, research |
| Scan Time | Standard | Faster |
| Cost | Lower | Higher |
| Operational Complexity | Moderate | High |
Most Indian diagnostic centers start with 1.5 Tesla due to balanced cost, throughput, and clinical versatility.
How to Evaluate an MRI Supplier
Before finalizing where to buy:
- Verify OEM authorization or refurbishment certification
- Request installation and acceptance testing protocols
- Confirm long-term service availability in your city
- Ask for uptime guarantees and spare parts access
- Review reference installations in India
MRI suppliers should be evaluated on service capability, parts availability, and installation experience—not only machine price.
Frequently Asked Questions (FAQ)
Hospitals can buy MRI machines from OEM-authorized distributors, certified refurbished equipment suppliers, or through government procurement channels.
Yes, if the system is certified, properly tested, and supported by trained service engineers with access to spare parts and helium services.
Typical installation takes 6–10 weeks, including civil work, shielding, magnet installation, and acceptance testing.
With proper maintenance, an MRI machine can operate for 12–18 years, depending on magnet health and software support.
MRI does not require radiation licensing, but facilities must follow AERB safety guidelines and international MRI safety standards.
Conclusion
Knowing where to buy an MRI machine in India involves understanding supplier types, compliance requirements, infrastructure readiness, and long-term service viability. Whether purchasing a new OEM system or a certified refurbished unit, informed evaluation ensures clinical reliability, patient safety, and sustainable operational costs.
For hospitals and diagnostic centers, the right MRI source is not the cheapest option—it is the one that delivers consistent image quality, uptime, and regulatory confidence over the machine’s full lifecycle.